Link: https://lore.kernel.org/r/20260217200002.683975158@linuxfoundation.org Tested-by: Florian Fainelli <florian.fainelli@broadcom.com> Tested-by: Takeshi Ogasawara <takeshi.ogasawara@futuring-girl.com> Tested-by: Peter Schneider <pschneider1968@googlemail.com> Tested-by: Jon Hunter <jonathanh@nvidia.com> Tested-by: Salvatore Bonaccorso <carnil@debian.org> Tested-by: Brett A C Sheffield <bacs@librecast.net> Tested-by: Mark Brown <broonie@kernel.org> Tested-by: Luna Jernberg <droidbittin@gmail.com> Tested-by: Ronald Warsow <rwarsow@gmx.de> Tested-by: Justin M. Forbes <jforbes@fedoraproject.org> Tested-by: Ron Economos <re@w6rz.net> Tested-by: Miguel Ojeda <ojeda@kernel.org> Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
24 lines
981 B
Plaintext
24 lines
981 B
Plaintext
What: /sys/bus/iio/devices/iio:deviceX/in_voltageY_sys_calibration
|
|
KernelVersion: 5.5
|
|
Contact: linux-iio@vger.kernel.org
|
|
Description:
|
|
This attribute, if available, initiates the system calibration procedure. This is done on a
|
|
single channel at a time. Write '1' to start the calibration.
|
|
|
|
What: /sys/bus/iio/devices/iio:deviceX/in_voltageY_sys_calibration_mode_available
|
|
KernelVersion: 5.5
|
|
Contact: linux-iio@vger.kernel.org
|
|
Description:
|
|
This attribute, if available, returns a list with the possible calibration modes.
|
|
There are two available options:
|
|
"zero_scale" - calibrate to zero scale
|
|
"full_scale" - calibrate to full scale
|
|
|
|
What: /sys/bus/iio/devices/iio:deviceX/in_voltageY_sys_calibration_mode
|
|
KernelVersion: 5.5
|
|
Contact: linux-iio@vger.kernel.org
|
|
Description:
|
|
This attribute, if available, sets up the calibration mode used in the system calibration
|
|
procedure. Reading returns the current calibration mode.
|
|
Writing sets the system calibration mode.
|