Link: https://lore.kernel.org/r/20260217200002.683975158@linuxfoundation.org Tested-by: Florian Fainelli <florian.fainelli@broadcom.com> Tested-by: Takeshi Ogasawara <takeshi.ogasawara@futuring-girl.com> Tested-by: Peter Schneider <pschneider1968@googlemail.com> Tested-by: Jon Hunter <jonathanh@nvidia.com> Tested-by: Salvatore Bonaccorso <carnil@debian.org> Tested-by: Brett A C Sheffield <bacs@librecast.net> Tested-by: Mark Brown <broonie@kernel.org> Tested-by: Luna Jernberg <droidbittin@gmail.com> Tested-by: Ronald Warsow <rwarsow@gmx.de> Tested-by: Justin M. Forbes <jforbes@fedoraproject.org> Tested-by: Ron Economos <re@w6rz.net> Tested-by: Miguel Ojeda <ojeda@kernel.org> Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
33 lines
1.0 KiB
Plaintext
33 lines
1.0 KiB
Plaintext
Palmas RTC controller bindings
|
|
|
|
Required properties:
|
|
- compatible:
|
|
- "ti,palmas-rtc" for palma series of the RTC controller
|
|
- interrupts: Interrupt number of RTC submodule on device.
|
|
|
|
Optional properties:
|
|
|
|
- ti,backup-battery-chargeable: The Palmas series device like TPS65913 or
|
|
TPS80036 supports the backup battery for powering the RTC when main
|
|
battery is removed or in very low power state. The backup battery
|
|
can be chargeable or non-chargeable. This flag will tells whether
|
|
battery is chargeable or not. If charging battery then driver can
|
|
enable the charging.
|
|
- ti,backup-battery-charge-high-current: Enable high current charging in
|
|
backup battery. Device supports the < 100uA and > 100uA charging.
|
|
The high current will be > 100uA. Absence of this property will
|
|
charge battery to lower current i.e. < 100uA.
|
|
|
|
Example:
|
|
palmas: tps65913@58 {
|
|
...
|
|
palmas_rtc: rtc {
|
|
compatible = "ti,palmas-rtc";
|
|
interrupt-parent = <&palmas>;
|
|
interrupts = <8 0>;
|
|
ti,backup-battery-chargeable;
|
|
ti,backup-battery-charge-high-current;
|
|
};
|
|
...
|
|
};
|