Files
cubelinux-kernel/tools/perf/pmu-events/arch/powerpc/compat/generic-events.json
T
Greg Kroah-Hartman 598cf27219 Linux 6.19.3
Link: https://lore.kernel.org/r/20260217200002.683975158@linuxfoundation.org
Tested-by: Florian Fainelli <florian.fainelli@broadcom.com>
Tested-by: Takeshi Ogasawara <takeshi.ogasawara@futuring-girl.com>
Tested-by: Peter Schneider <pschneider1968@googlemail.com>
Tested-by: Jon Hunter <jonathanh@nvidia.com>
Tested-by: Salvatore Bonaccorso <carnil@debian.org>
Tested-by: Brett A C Sheffield <bacs@librecast.net>
Tested-by: Mark Brown <broonie@kernel.org>
Tested-by: Luna Jernberg <droidbittin@gmail.com>
Tested-by: Ronald Warsow <rwarsow@gmx.de>
Tested-by: Justin M. Forbes <jforbes@fedoraproject.org>
Tested-by: Ron Economos <re@w6rz.net>
Tested-by: Miguel Ojeda <ojeda@kernel.org>
Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
2026-02-19 16:33:27 +01:00

118 lines
3.0 KiB
JSON

[
{
"EventCode": "0x600F4",
"EventName": "PM_CYC",
"BriefDescription": "Processor cycles."
},
{
"EventCode": "0x100F2",
"EventName": "PM_CYC_INST_CMPL",
"BriefDescription": "1 or more ppc insts finished"
},
{
"EventCode": "0x100f4",
"EventName": "PM_FLOP_CMPL",
"BriefDescription": "Floating Point Operations Finished."
},
{
"EventCode": "0x100F6",
"EventName": "PM_L1_ITLB_MISS",
"BriefDescription": "Number of I-ERAT reloads."
},
{
"EventCode": "0x100F8",
"EventName": "PM_NO_INST_AVAIL",
"BriefDescription": "Number of cycles the ICT has no itags assigned to this thread."
},
{
"EventCode": "0x100fc",
"EventName": "PM_LD_CMPL",
"BriefDescription": "Load instruction completed."
},
{
"EventCode": "0x200F0",
"EventName": "PM_ST_CMPL",
"BriefDescription": "Stores completed from S2Q (2nd-level store queue)."
},
{
"EventCode": "0x200F2",
"EventName": "PM_INST_DISP",
"BriefDescription": "PowerPC instruction dispatched."
},
{
"EventCode": "0x200F4",
"EventName": "PM_RUN_CYC",
"BriefDescription": "Processor cycles gated by the run latch."
},
{
"EventCode": "0x200F6",
"EventName": "PM_L1_DTLB_RELOAD",
"BriefDescription": "DERAT Reloaded due to a DERAT miss."
},
{
"EventCode": "0x200FA",
"EventName": "PM_BR_TAKEN_CMPL",
"BriefDescription": "Branch Taken instruction completed."
},
{
"EventCode": "0x200FC",
"EventName": "PM_L1_ICACHE_MISS",
"BriefDescription": "Demand instruction cache miss."
},
{
"EventCode": "0x200FE",
"EventName": "PM_L1_RELOAD_FROM_MEM",
"BriefDescription": "L1 Dcache reload from memory"
},
{
"EventCode": "0x300F0",
"EventName": "PM_ST_MISS_L1",
"BriefDescription": "Store Missed L1"
},
{
"EventCode": "0x300FC",
"EventName": "PM_DTLB_MISS",
"BriefDescription": "Data PTEG reload"
},
{
"EventCode": "0x300FE",
"EventName": "PM_DATA_FROM_L3MISS",
"BriefDescription": "Demand LD - L3 Miss (not L2 hit and not L3 hit)"
},
{
"EventCode": "0x400F0",
"EventName": "PM_LD_MISS_L1",
"BriefDescription": "L1 Dcache load miss"
},
{
"EventCode": "0x400F2",
"EventName": "PM_CYC_INST_DISP",
"BriefDescription": "Cycle when instruction(s) dispatched."
},
{
"EventCode": "0x400F6",
"EventName": "PM_BR_MPRED_CMPL",
"BriefDescription": "A mispredicted branch completed. Includes direction and target."
},
{
"EventCode": "0x400FA",
"EventName": "PM_RUN_INST_CMPL",
"BriefDescription": "PowerPC instruction completed while the run latch is set."
},
{
"EventCode": "0x400FC",
"EventName": "PM_ITLB_MISS",
"BriefDescription": "Instruction TLB reload (after a miss), all page sizes. Includes only demand misses."
},
{
"EventCode": "0x400fe",
"EventName": "PM_LD_NOT_CACHED",
"BriefDescription": "Load data not cached."
},
{
"EventCode": "0x500fa",
"EventName": "PM_INST_CMPL",
"BriefDescription": "Instructions."
}
]