Files
cubelinux-kernel/Documentation/hwmon/ibmaem.rst
T
Greg Kroah-Hartman 598cf27219 Linux 6.19.3
Link: https://lore.kernel.org/r/20260217200002.683975158@linuxfoundation.org
Tested-by: Florian Fainelli <florian.fainelli@broadcom.com>
Tested-by: Takeshi Ogasawara <takeshi.ogasawara@futuring-girl.com>
Tested-by: Peter Schneider <pschneider1968@googlemail.com>
Tested-by: Jon Hunter <jonathanh@nvidia.com>
Tested-by: Salvatore Bonaccorso <carnil@debian.org>
Tested-by: Brett A C Sheffield <bacs@librecast.net>
Tested-by: Mark Brown <broonie@kernel.org>
Tested-by: Luna Jernberg <droidbittin@gmail.com>
Tested-by: Ronald Warsow <rwarsow@gmx.de>
Tested-by: Justin M. Forbes <jforbes@fedoraproject.org>
Tested-by: Ron Economos <re@w6rz.net>
Tested-by: Miguel Ojeda <ojeda@kernel.org>
Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
2026-02-19 16:33:27 +01:00

45 lines
1.4 KiB
ReStructuredText

Kernel driver ibmaem
====================
This driver talks to the IBM Systems Director Active Energy Manager, known
henceforth as AEM.
Supported systems:
* Any recent IBM System X server with AEM support.
This includes the x3350, x3550, x3650, x3655, x3755, x3850 M2,
x3950 M2, and certain HC10/HS2x/LS2x/QS2x blades.
The IPMI host interface
driver ("ipmi-si") needs to be loaded for this driver to do anything.
Prefix: 'ibmaem'
Datasheet: Not available
Author: Darrick J. Wong
Description
-----------
This driver implements sensor reading support for the energy and power meters
available on various IBM System X hardware through the BMC. All sensor banks
will be exported as platform devices; this driver can talk to both v1 and v2
interfaces. This driver is completely separate from the older ibmpex driver.
The v1 AEM interface has a simple set of features to monitor energy use. There
is a register that displays an estimate of raw energy consumption since the
last BMC reset, and a power sensor that returns average power use over a
configurable interval.
The v2 AEM interface is a bit more sophisticated, being able to present a wider
range of energy and power use registers, the power cap as set by the AEM
software, and temperature sensors.
Special Features
----------------
The "power_cap" value displays the current system power cap, as set by the AEM
software. Setting the power cap from the host is not currently supported.